A filter press feed duty is a falling curve: high flow and low pressure with empty chambers, then almost no flow and maximum pressure once the cake forms. Both the SYA and ZJE charts on file run at 1480 r/min up to 76 m head, so select on final pressure, not initial flow.
Construction, model range, wetted materials and duty limits for this series. Figures come from the charts and manuals on file; values not published are marked "per supplied documents".

Horizontal filter press feed pump. SYA / ZJE pumps are designed for filter press feeding, where flow falls and pressure rises as the press fills. They must run stably across a wide duty range; twin-impeller or two-stage builds cover the higher pressure at the end of the cycle.
For example 65SYA75-30: the leading number is a bore designation and the following figures usually denote flow and head/power. In 65ZJE-II the II denotes a two-stage (twin-impeller) build. Codes vary between manufacturers.
Published specifications are stated as flow, head and motor power combinations; exact values follow written confirmation.
| Model | Max. power kW | Q m³/h | H m | n r/min | Max. eff. % |
|---|---|---|---|---|---|
| 65ZJE-Ⅱ | 1480 | 27.5 41.4 55.2 69.0 80.0 | 22.3 | Y225S-4 | 30 |
| 65ZJE-Ⅱ | 1480 | 27.5 41.4 55.2 69.0 80.0 | 22.3 | Y225S-4 | 37 |
| 80ZJE-Ⅱ | 1480 | 40.0 60.0 80.0 100 115 | 32 | Y225S-4 | 37 |
| 80ZJE-Ⅱ | 1480 | 40.0 60.0 80.0 100 115 | 32 | Y225M-4 | 45 |
| 100ZJE-Ⅱ | 1480 | 56.0 85.0 113 150 169 | 49 | Y225M-4 | 45 |
| 100ZJE-Ⅱ | 1480 | 56.0 85.0 113 150 169 | 49 | Y225M-4 | 55 |
| 125ZJE-Ⅱ | 1480 | 70.0 105 140 186 245 | 62.5 | Y225M-4 | 55 |
| 125ZJE-Ⅱ | 1480 | 70.0 105 140 186 245 | 62.5 | Y280S-4 | 75 |
| 125ZJE-Ⅱ | 1480 | 79.7 119 159 211 279 | 78.2 | Y280S-4 | 75 |
| 125ZJE-Ⅱ | 1480 | 79.7 119 159 211 279 | 78.2 | Y280M-4 | 90 |
| 125ZJE-Ⅱ | 1480 | 58.0 87.0 116 154 203 | 64.7 | Y280S-4 | 75 |
| 125ZJE-Ⅱ | 1480 | 58.0 87.0 116 154 203 | 64.7 | Y280M-4 | 90 |
The industry pages behind these duties set out recommended series, wear parts and field checks.
Material follows the medium; sealing follows suction pressure and whether dilution is allowed.
Each part page lists the basic number, material options and applicable models. One basic number maps to different part numbers across frames, so check against the nameplate.

Mainly high-chrome wear alloy (A05 / Cr26 / Cr27); rubber or p…

High-chrome wear alloy, wear-resistant rubber or polyurethane:…

High-chrome wear alloy, rubber lining or wear/corrosion-resist…

Wear-resistant alloy, stainless or 3Cr13-type martensitic stee…

Heavy rolling bearings (cylindrical roller plus thrust/angular…
Excerpts that apply to this series; read the full text on the online reading page.
Both are filter press feed pumps listed in separate charts at 1480 r/min. Build codes and the press sizes they suit differ; select on chamber volume, feed time and final pressure.
Convert the press maximum working pressure into head, then add pipe losses and static lift. A 1.6 MPa press needs roughly 163 m, so a 76 m catalogue value cannot be applied directly.
It will fill the press but is not recommended long term. A standard pump is efficient at high flow, so running at low flow and high pressure leaves the efficient zone, adding heat, vibration and seal wear.
Send the medium, particle size and solids content, flow, head, pH and temperature, plus installation conditions (pit depth or line length). For parts, add the pump model or a photo of the worn part.
We reply within one business day. You can also call +86 188 0321 2220.
Please provide the pump model, nameplate data and duty parameters by phone or email. Performance charts and manuals can be read online.