The ZGB series is a heavy duty, high-head pump developed for ash and slag handling. Its pump end, shaft seal and drive end can be serviced separately; it supports series staging and suits continuous abrasive duties such as power plant ash removal and long-distance tailings transport.
Each segment explained against published industry naming conventions.
| Field | Meaning |
|---|---|
| Discharge bore | 300 mm |
| Series code | Z slurry pump / G high head / B series code |
| Series-operation mark | No mark (single stage or stages 1-2) |
ZGB Series Slurry Pump
Double casing with separately replaceable liners; discharge rotatable through eight positions at 45 degree intervals.
Back vanes on the impeller shrouds reduce leakage and improve axial thrust behaviour.
An expeller plus packing combination can operate where slurry dilution is not acceptable.
Clockwise rotation viewed from the drive end; motor direction must be verified before start-up.
Hydraulic ash and slag handling in power plants
Long-distance tailings lines and series systems
High-head continuous transfer in metallurgy and mining

High-chrome wear alloy wetted parts; expeller, relief cover and shaft sleeve are made of wear-resistant materials as well.
Expeller plus packing combination or mechanical seal. With series staging, seal-water pressure for stage two and above is calculated against the stage count.
Clear-water data for this model, full series charts and notes from the manuals.
| Parameter | Value / description |
|---|---|
| Discharge bore | 300 mm |
| Series code | Z slurry pump / G high head / B series code |
| Series-operation mark | No mark (single stage or stages 1-2) |
| Construction | Horizontal, single-stage single-suction, overhung double-casing heavy duty slurry pump |
| Wetted material options | High-chrome wear alloy wetted parts; expeller, relief cover and shaft sleeve are made of wear-resistant materials as well. |
| Shaft seal options | Expeller plus packing combination or mechanical seal. With series staging, seal-water pressure for stage two and above is calculated against the stage count. |
| Published series coverage | Typical coverage: discharge bores about 65-300 mm, flow about 50-1800 m3/h and head about 50-94 m. |
Clear-water data for this particular model is not listed separately; the common coverage of its series is given below for reference only. Expand the full series charts where available. Binding values follow the supplied documents and written confirmation.
Typical coverage: discharge bores about 65-300 mm, flow about 50-1800 m3/h and head about 50-94 m.
Compiled from the AH / L / G, SP, ZJ and ZGB pump manuals, with links to the full texts.
Horizontal slurry pumps are overhung centrifugal pumps for abrasive or corrosive slurry, widely used in metallurgy, mining, petrochemical, coal, power, dredging, building materials and municipal works. Families cover heavy duty (AH, HH), light duty (L), gravel / dredging (D, G) and rubber-lined (AHR, LR, MR) builds. Pumps may be staged in series within the allowable working pressure.
Heavy duty AH and HH pumps use a double casing: an outer pressure-retaining casing and cover in grey or ductile iron, vertically split and bolted, plus replaceable wear liners (impeller, volute liner, throat bush and frame plate liner) in metal or rubber. The discharge can be rotated in eight positions at 45 degree intervals. D and G gravel pumps use a single casing with all wetted parts in wear-resistant metal. Apart from the wet end, all horizontal types share the same frame and bearing assembly, with a large-diameter shaft and short overhang.
Preheat bearing inner rings to no more than 120 C during assembly and seat them firmly against the shaft shoulder or grease retainer. Inner rings, outer rings and spacers of double-row tapered roller bearings form a matched set and must not be interchanged. Wet-end assembly order: seals, frame plate liner with its locating nuts, impeller, volute liner clamped in place, then throat bush and cover plate. Lift crated pumps by the marked sling points without shock or excessive tilt; lifting eyes on the casing are for dismantling the casing only, never for lifting the complete pump.
Three shaft seal arrangements are common: expeller, packed gland and mechanical seal. The expeller seal suits single-stage pumps (or the first stage of a series set) where inlet positive pressure is below 10 percent of discharge pressure; it needs no seal water and does not dilute the slurry. A packed gland is simple to service but requires seal water. A mechanical seal gives the best sealing and requires cooling water. A packed gland comprises the stuffing box, shaft sleeve, spacer, O-rings, packing, packing spacer, lantern ring and gland. Bearings are grease or oil lubricated, with oil lubrication preferred for high temperature or large pumps.
Before start-up check that foundation and coupling bolts are tight, turn the shaft by hand in the direction of rotation without rubbing, verify motor rotation against the arrow on the casing, and align the V-belts square to the pulleys. Starting on clean water is preferable before slurry is introduced. During operation watch the instruments for flow, velocity and current and correct any abnormality. Where possible flush with clean water before stopping, then stop the pump before closing the valve. For vertical sump pumps, turn on the guide bearing flush water five minutes before starting and close it five minutes after stopping.
Check impeller-to-throatbush clearance, bearing temperature and lubrication, seal water pressure and flow, and wear of wetted parts on a regular basis. A worn impeller reduces flow and head and raises vibration and noise, so adjust the clearance or replace the wear parts. Typical faults are insufficient flow or head, bearing overheating, vibration, seal leakage and cavitation, usually caused by blockages, wrong rotation, low speed, air ingress on the suction side, inadequate NPSH or loss of dynamic balance. Record basic part numbers and material suffixes and verify them against the pump model and supplied documents.
ZGB(P) pumps are horizontal, single-stage, single-suction, overhung double-casing centrifugal pumps. The suction is horizontal and rotation is clockwise viewed from the drive end; reverse rotation must never be allowed.
Expelling vanes on both impeller shrouds reduce leakage, and the discharge can be rotated in eight positions at 45 degree intervals.
With a packing plus expeller seal, seal water pressure is generally not below 0.2 MPa; with a mechanical seal it is normally 0.1 MPa above discharge pressure. Bearings are oil lubricated with water cooling.
Bearing clearance is factory set between 0.2 and 0.5 mm and must be restored to that value whenever bearings are dismantled or replaced.
Extracts from the original manuals are shown in the Chinese edition; the full texts are available via the links below.
Open each part page for function, material and replacement notes.
Models, parts and manuals related to this product.
Send the model or worn-part dimensions, or call +86 188 0321 2220 / email sale@pumpq.com.
We reply within one business day. You can also call +86 188 0321 2220.
Please provide the pump model, nameplate data and duty parameters by phone or email. Performance charts and manuals can be read online.